The designed mos tube switch circuit has not played an anti-reverse effect, why?

Hardware design
Juli 03, 2020 by Jessy 521

I use the NCE3401 Pmos tube, I will automatically connect the S and D pins wrong, regardless of this, according to the connection in the figure, D to S is always on, assuming that when VIN input 12V, Vbus does not input voltage, In theory, the PMOS is cut off. There should be a diode reversed from S to D at 12V. The voltage should not pass. Theoretically, VD=Vbus is 0V, but I measured the vbus to be more than 10V. This is what happened.

Alle Kommentare

user image

Benicio Veröffentlicht am July 3, 2020

I think it may be possible to analyze this way: DS leakage current also exists in the off state of the Pmos tube, which can be regarded as a large resistance R1 between DS. Vs=12-0.3=11.7V. When you measure the floating Vbus pin, the multimeter also has a large resistance to ground, R2, R1 and R2, and you get a voltage of more than 10V. You can try to add a resistance of tens of K between Vbus and ground. It is estimated that this voltage will drop.

0
user image

Colbie Veröffentlicht am July 3, 2020

The parasitic diode inside the MOS tube has always been in the on state, and the control pin will be turned on regardless of the level. Now this way, it does not play the anti-reverse effect you want.

0
user image

Bernadette Veröffentlicht am July 3, 2020

Judging from your circuit diagram alone, there is no voltage in VBUS. Is it that the MOS is reversed or find it from other places?