RFQ/BOM 0 Anmelden / Registrieren

Wähle deinen Standort

Benutzerbild

Why is the on-load voltage higher than the no-load voltage when the primary side feedback IC is used as a small power supply?

Hardware design
Oktober 21, 2020 by Erwin 1395

Recently, two different ICs have encountered problems. Some primary-side feedback ICs are used as low-power power supplies. Most of them are below 10W. The load voltage of the power supply is higher than the no-load voltage? For example, a 15V 0.3A charger has a no-load voltage of 15V. This is easy to adjust, but during the test, the load voltage will become 15.6V 0.26A. What is the situation?

Alle Kommentare

user image

Venus Veröffentlicht am October 21, 2020

It seems to be an edge-controlled IC. The auxiliary winding of your transformer must be specially coupled to facilitate edge voltage sampling.

1
user image

Maureen Veröffentlicht am October 21, 2020

Related to the transformer, it is mainly the transformer structure.

0
user image

Tamsin Veröffentlicht am October 21, 2020

What topology? Does the primary side feedback collect the voltage of the primary side transformer? Could this be the cause of leakage?

0

Schreiben Sie eine Antwort